Island low-temperature showcase Venezia (single-volume)

Island low-temperature showcase Venezia (single-volume)

Bonnets (island freezer showcases) can be offered with different showcases to create a complete proposal for staffing stores of various formats. The design of the showcase allows to present the goods to the buyer maximum available, including through the panoramic side glasses.

Standard equipment

  • the showcase is equipped with a powerful paired low-temperature unit that allows you to maintain the temperature in the bonnet up to -24 °С;
  • decorative elements are made of aluminum profile;- forced air circulation in the volume;- condensate evaporator tank;
  • energy saving night blinds;- energy-saving LED-lighting of internal volume;
  • the bannet is equipped with the electronic control panel with function of an automatic defrosting of the evaporator;
  • refrigerated display cases are made for remote cold supply.

Options

  • stand alone;- wall;- end;- side walls with panoramic glass or deaf;
  • it is possible to manufacture showcases with a superstructure with illuminated shelves;
  • it is possible to supply a display case with a solenoid valve for supplying a refrigerant;
  • the ability to choose the color of the base;
  • the possibility of docking showcases in line;
  • the use of built-in hardened glass covers reduces the energy consumption by 30% and limits the dispersion of cold into the room.

 Warranty from the manufacturer – 2 years

Technical data

Technical dataVenezia-1,25Venezia -1,5Venezia endVenezia wall
Length L, мм, with sidewalls2055267539251975260038502000197526753925
Width, mm1240150010801060
Height, mm950910
Useful volume*, dm34116059054706509504005507301100
Display area, m21,722,33,452,22,94,31,41,52,03,0
Mass of uniformly loaded product, kg, not more than861251901101602408085110165
Ambient temperature, °С12 – 25
Temperature in internal volume, °Сfrom -18 to -24**
AC mains voltage, V380±38
Refrigerating capacity**, kW, not more than1,531,52,501,52,03,01,4100014002100
Maximum power consumption, kW2,734,56,53,94,76,32,82,624,05,02
Daily electric energy consumption at ambient air temperature of 22°С, kWh11,418,624,38,710,51310,48,6413,115,8
Mass, kg112125180190250300220175200350
Cooling typedynamic
Connecting dimensions, mm, no more than
diameter of drainage pipe
diameter of liquid pipe
suction pipe diameter
40
10
16
*- useful volume is the volume limited by the inner lining and the plane passing through the loading line.